ISO 15712-3:2005 specifies a calculation model to estimate the sound insulation or the sound pressure level difference of a façade or other external surface of a building. The calculation is based on the sound reduction index of the different elements from which the façade is constructed and it includes direct and flanking transmission. The calculation gives results which correspond approximately to the results from field measurements according to ISO 140-5. Calculations can be carried out for frequency bands or for single number ratings.
The calculation results can be used also for calculating the indoor sound pressure level due to for instance road traffic; this use is treated in the informative annex D.
ISO 15712-3:2005 describes the principles of the calculation model, lists the relevant quantities and defines its applications and restrictions. It is intended for acoustical experts and provides the framework for the development of application documents and tools for other users in the field of building construction, taking into account local circumstances.
The model is based on experience with predictions for dwellings; it can also be used for other types of buildings provided the dimensions of constructions are not too different from those in dwellings.
WITHDRAWN
ISO 15712-3:2005
95.99
Withdrawal of Standard
Jul 17, 2017
PUBLISHED
ISO 12354-3:2017
Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.